COMBINATION METER REASSEMBLY

PROCEDURE


  1. INSTALL METER DISPLAY PANEL


    1. Install the meter display panel to the meter ECU.

    2. Connect the 2 wire harnesses to the 3 connectors and push the 3 connector locks to lock them.

      Note


      • Do not forcibly insert the wire harness into the connector.

      • Connect the wire harness by holding both ends and inserting directly into the connector.

      • Do not scratch or dirty the contacts of the wire harness.

    3. Check that the wire harness is connected.

      OK
      The wire harness is not at an angle.
      The wire harness is firmly inserted into the connector.
      A0018ZOE02
      Text in Illustration
      *1 Connector Lock *2 Wire harness
      A001BDP Push - -
  2. INSTALL COMBINATION METER COVER


    1. Install the combination meter cover with the 10 screws.

  3. INSTALL COMBINATION METER GLASS


    1. Attach the 6 claws to install the combination meter glass.

    2. Install the 2 screws.

  4. INSTALL NO. 1 COMBINATION METER BRACKET


    1. Install the No. 1 combination meter bracket with the 4 screws.