REAR DOOR LOCK INSPECTION

PROCEDURE


  1. INSPECT REAR DOOR LOCK ASSEMBLY LH


    1. Apply battery voltage to the door lock motor and check operation of the door lock motor.

      A001AW4E04
      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal A4 (L)

      Battery negative (-) → Terminal A1 (UL)

      Lock

      Battery positive (+) → Terminal A1 (UL)

      Battery negative (-) → Terminal A4 (L)

      Unlock

      • If the result is not as specified, replace the rear door lock assembly LH.

    2. Measure the resistance of the door lock position switch.

      Standard resistance
      Tester Connection Switch Condition Specified Condition
      A-6 (LSSR) - A-9 (E) Unlock Below 1 Ω
      A-6 (LSSR) - A-9 (E) Lock 10 kΩ or higher

      • If the result is not as specified, replace the rear door lock assembly LH.

      Text in Illustration
      *a

      Component without harness connected:

      (Rear Door Lock Assembly LH)

      *b Connector A
      *c Connector B
      *d Unlock
      *e Lock
    3. Closer motor operation inspection

      A001DW3E03

      1. Set the rear door lock assembly LH to the half latch position.

      2. When battery voltage is applied as shown below to the terminals of connector B of the rear door lock assembly LH, check the operation of the door closer.

        OK
        Measurement Condition Closer motor operation

        Battery positive (+) → Terminal B1 (CLM+)

        Battery negative (-) → Terminal B5 (CLM-)

        Moves to full latch position

        • If the result is not as specified, replace the rear door lock assembly LH.

        Text in Illustration
        *a

        Component without harness connected:

        (Rear Door Lock Assembly LH)

        *b Connector A
        *c Connector B
        *d Half Latch
        *e Full Latch
  2. INSPECT REAR DOOR LOCK ASSEMBLY RH


    1. Apply battery voltage to the door lock motor and check operation of the door lock motor.

      A001BCTE04
      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal A4 (L)

      Battery negative (-) → Terminal A1 (UL)

      Lock

      Battery positive (+) → Terminal A1 (UL)

      Battery negative (-) → Terminal A4 (L)

      Unlock

      • If the result is not as specified, replace the rear door lock assembly RH.

    2. Measure the resistance of the door lock position switch.

      Standard resistance
      Tester Connection Switch Condition Specified Condition
      A-6 (LSSR) - A-9 (E) Unlock Below 1 Ω
      A-6 (LSSR) - A-9 (E) Lock 10 kΩ or higher

      • If the result is not as specified, replace the rear door lock assembly RH.

      Text in Illustration
      *a

      Component without harness connected:

      (Rear Door Lock Assembly RH)

      *b Connector A
      *c Connector B
      *d Unlock
      *e Lock
    3. Closer motor operation inspection

      A001DNYE03

      1. Set the rear door lock assembly RH to the half latch position.

      2. When battery voltage is applied as shown below to the terminals of connector B of the rear door lock assembly RH, check the operation of the door closer.

        OK
        Measurement Condition Closer motor operation

        Battery positive (+) → Terminal B1 (CLM+)

        Battery negative (-) → Terminal B5 (CLM-)

        Moves to full latch position

        • If the result is not as specified, replace the rear door lock assembly RH.

        Text in Illustration
        *a

        Component without harness connected:

        (Rear Door Lock Assembly LH)

        *b Connector A
        *c Connector B
        *d Half Latch
        *e Full Latch