SECURITY HORN ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT SECURITY HORN ASSEMBLY (for LHD)


    1. A001F6A

      Apply battery voltage and check operation of the horn.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Horn bracket

      Horn sounds

      If the result is not as specified, replace the security horn assembly.

  2. INSPECT SECURITY HORN ASSEMBLY (for RHD)


    1. A001BFR

      Apply battery voltage and check operation of the horn.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Horn bracket

      Horn sounds

      If the result is not as specified, replace the security horn assembly.