ROOM TEMPERATURE SENSOR(for Rear Side) INSPECTION

PROCEDURE


  1. INSPECT COOLER THERMISTOR


    1. Measure the resistance according to the value(s) in the table below.

      A0018XVE01
      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
      1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
      1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
      1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
      1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
      1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
      1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
      1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
      1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
      1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
      1 - 2 60°C (140°F) 0.36 to 0.50 kΩ

      Note


      • Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Text in Illustration
      *a

      Component without harness connected

      (Cooler Thermistor)

      *b Resistance (kΩ)
      *c Temperature

      Tech Tips

      As the temperature increases, the resistance decreases (see the graph).

      If the result is not as specified, replace the cooler thermistor.