| DTC Code | DTC Name |
|---|---|
| B1415/15 | Driver Side Duct Sensor |
DESCRIPTION
The air duct sensor (for driver side) detects the register temperature and sends the appropriate signals to the air conditioning amplifier.
| DTC No. | Detection item | Trouble Area |
|---|---|---|
| B1415/15 | Air duct sensor circuit (for driver side) (Open or short) |
|
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (DUCT SENSOR (for Driver Side))
Use the Data List to check if the duct sensor (for driver side) is functioning properly.
| Tester Display | Measurement Item / Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Duct Sensor (D Side) | Duct sensor (for driver side) / Min.: -12.7°C (9.14°F) Max.: 76.55°C (169.79°F) |
Actual duct temperature is displayed (for driver side) | - |
| OK |
|---|
| The display is as specified in the normal condition. |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
| B |
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| A |
|
CHECK AIR CONDITIONING AMPLIFIER (TFAL - SG-2, TFAR - SG-3 VOLTAGE)
| *a | Component with harness connected: (Air Conditioning Amplifier) |
| *b | for LHD: |
| *c | for RHD: |
Remove the air conditioning amplifier with its connectors still connected Click here.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
|
Tech Tips
As the temperature increases, the voltage decreases.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) |
B |
| OK (Checking from the DTC) | C |
| B |
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| A |
|
CHECK AIR DUCT SENSOR
Remove the air duct sensor Click here.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
As the temperature increases, the resistance decreases.
| NG |
|
REPLACE AIR DUCT SENSOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT SENSOR)
Disconnect the L14*1 or L87*2 air duct sensor connector.
Disconnect the L77 air conditioning amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |