BATTERY CURRENT SENSOR INSPECTION

CAUTION / NOTICE / HINT

Tech Tips


  • Use the same procedure for RHD and LHD vehicles.

  • The procedure listed below is for LHD vehicles.

PROCEDURE


  1. INSPECT GROUND WIRE (BATTERY CURRENT SENSOR)

    A001F1ZE39
    Text in Illustration
    *a

    Component without harness connected

    {Ground Wire (Battery Current Sensor)}


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Specified Condition

      Tester (+) → 2 (VC5)

      Tester (-) → 4 (E2)

      3 k to 10 kΩ

      Tester (+) → 2 (VC5)

      Tester (-) → 3 (IB)

      0.5 kΩ or less

      Tester (+) → 3 (IB)

      Tester (-) → 4 (E2)

      3 k to 10 kΩ

      If the result is not as specified, replace the ground wire (battery current sensor).

    2. A0019A4E02
      Text in Illustration
      *a

      Component without harness connected

      {Ground Wire (Battery Current Sensor)}

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (THB) - 4 (E2) 20 to 30°C (68 to 86°F) 1.5 k to 2.5 kΩ
      (0 to 70°C (32 to 158°F)) (0.3 k to 6.0 kΩ)

      Note

      The temperature shown in the condition is for the area surrounding the sensor, not the sensor itself.