1UR-FE LUBRICATION SERVICE DATA

LUBRICATION SYSTEM
Oil pressure at idle speed

70 kPa (0.7 kgf/cm2, 10.1 psi) or more

at 2500 rpm

220 kPa (2.2 kgf/cm2, 31.9 psi) or more

OIL LEVEL SENSOR
Tester Connection Condition Specified Condition
1 - 2 ON, 20°C (68°F) Below 1Ω
OFF, 20°C (68°F) Below 1Ω
ON, 60°C (140°F) Below 1Ω
ON, 60°C (140°F) 10 kΩ or higher
OIL PUMP
Tip clearance Standard 0.180 to 0.300 mm (0.00709 to 0.0118 in.)
Maximum 0.300 mm (0.0118 in.)
Side clearance Standard 0.030 to 0.060 mm (0.00118 to 0.00236 in.)
Maximum 0.060 mm (0.00236 in.)
Body clearance Standard 0.175 to 0.250 mm (0.00689 to 0.00984 in.)
Maximum 0.250 mm (0.00984 in.)