PURGE VALVE INSPECTION

PROCEDURE


  1. INSPECT VACUUM SWITCHING VALVE (PURGE VSV)


    1. A001D6LE01

      Measure the resistance of the purge VSV.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω
      1 - Body ground Always 10 MΩ or higher
      2 - Body ground Always 10 MΩ or higher

      If the result is not as specified, replace the purge VSV.

    2. Check operation of the purge VSV.


      1. A001DLJE01
        *1 Air
        *2 Does not flow

        Check that air does not flow from port E to port F.

      2. A0019A8E01
        *1 Air

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.