INSPECT SHIFT SOLENOID VALVE S1
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Shift Solenoid Valve S1 |
Connect a positive (+) lead from battery to the terminal of the shift solenoid valve S1 connector, and a negative (-) lead to the shift solenoid valve S1 body, and check the operation of the valve.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve S1.
INSPECT SHIFT SOLENOID VALVE S2
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Shift Solenoid Valve S2 |
Connect a positive (+) lead from battery to the terminal of the shift solenoid valve S2 connector, and a negative (-) lead to the shift solenoid valve S2 body, and check the operation of the valve.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve S2.
INSPECT SHIFT SOLENOID VALVE SLT
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
Connect the positive (+) lead with a 21 W bulb from the battery to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SLT connector and check the operation of the valve.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve SLT.
INSPECT SHIFT SOLENOID VALVE SL
w/o Flex Lock-up:
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Shift Solenoid Valve SL |
Connect a positive (+) lead from battery to the terminal of the shift solenoid valve SL connector, and a negative (-) lead to the shift solenoid valve SL body, and check the operation of the valve.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve SL.
INSPECT SHIFT SOLENOID VALVE SLU
w/ Flex Lock-up:
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Shift Solenoid Valve SLU) |
Connect the positive (+) lead with a 21 W bulb from the battery to terminal 1 and the negative (-) lead to terminal 2 of the shift solenoid valve SLU connector and check the operation of the valve.
| OK |
|---|
| The valve moves and makes an operating sound. |
If the result is not as specified, replace the shift solenoid valve SLU.