INSPECT SHIFT SOLENOID VALVE SLT
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve.
INSPECT SHIFT SOLENOID VALVE SL
| *a | Component without harness connected (Shift Solenoid Valve SL) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve.
INSPECT SHIFT SOLENOID VALVE S1 AND S2
| *a | Component without harness connected (Shift Solenoid Valve S1 and S2) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the shift solenoid valve.