    INSTALL ATF TEMPERATURE SENSOR


    1. Coat the O-ring of the ATF temperature sensor with ATF.

    2. Using a 19 mm union nut wrench, install the ATF temperature sensor.

      15 N*m 150 kgf*cm 11 ft.*lbf
      Note:

      Use the formula to calculate special torque values for situations where a union nut wrench is combined with a torque wrench (Click here).

    3. Connect the connector.

  2. Click here

    CHECK AUTOMATIC TRANSMISSION FLUID LEVEL