КЛАПАН ПРОДУВКИ АДСОРБЕРА ПРОВЕРКА


  1. INSPECT PURGE VSV


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω
      1 - Body ground Always 10 MΩ or higher
      2 - Body ground

      Tech Tips

      When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C (68°F).

      If the result is not as specified, replace the purge VSV.

    2. Check the operation.


      1. A003H7GE06
        Text in Illustration
        *a Port E
        *b Port F
        A003DCD Air

        Check that air does not flow from port E to port F.

      2. Apply battery voltage across the terminals.

      3. A003FI8E05
        Text in Illustration
        *a Port E
        *b Port F
        A003DCD Air

        Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.