INSTALL CHARCOAL CANISTER ASSEMBLY
Install the charcoal canister assembly to the bracket.
Connect the 2 purge line hoses, and slide the 2 clamps to secure the hoses.
INSTALL BATTERY CARRIER
Install the battery carrier with the 3 bolts.
| 8.0 N*m | 82 kgf*cm | 71 in.*lbf |
Attach the wire harness clamp to the battery carrier.
Connect the battery thermometer sensor connector.
INSTALL BATTERY
INSTALL BATTERY CLAMP SUB-ASSEMBLY
Temporarily install the bolt and tighten the nut.
Adjust the battery clamp sub-assembly position.
Tighten the bolt and nut.
| 5.4 N*m | 55 kgf*cm | 48 in.*lbf |
CONNECT CABLE TO POSITIVE BATTERY TERMINAL
Connect the positive (+) battery terminal to the battery and tighten the nut.
| 5.4 N*m | 55 kgf*cm | 48 in.*lbf |
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Connect the negative (-) battery terminal to the battery and tighten the nut.
| 5.4 N*m | 55 kgf*cm | 48 in.*lbf |
When disconnecting the cable some systems need to be initialized after the cable is reconnected (Click here).
PERFORM INITIALIZATION