    INSPECT UREA PUMP


    1. Inspect the level sensor.


      1. A003FVME01

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        14(LV1) - 6(ELV1) Float position is upper 53.56 to 56.08 kΩ
        Float position is lower 1.40 to 1.46 kΩ
        Table 1. Text in Illustration
        *a

        Component without harness connected

        (Urea Pump)

        *b Upper
        *c Lower
    2. Inspect the tank heater.


      1. A003DT1E01

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        9(TH+) - 11(TH-) 25°C (77°F) 1.39 to 1.54 kΩ
        Table 2. Text in Illustration
        *a

        Component without harness connected

        (Urea Pump)

    3. Inspect the temperature sensor.


      1. A003DT1E02

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1(TUW) - 2(ETUW) 20°C (68°F) 2.47 to 2.56 kΩ
        30°C (86°F) 1.69 to 1.75 kΩ
        Table 3. Text in Illustration
        *a

        Component without harness connected

        (Urea Pump)

    4. Inspect the pump motor.


      1. A003DT1E03

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        7(PHAA) - 8(PHAB) 20 to 30 °C (68 to 86°F) 0.35 to 0.43 Ω
        7(PHAA) - 16(PHAC)
        8(PHAB) - 16(PHAC)
        7(PHAA) - 15(MGND) Always 10 kΩ or higher
        8(PHAB) - 15(MGND)
        16(PHAC) - 15(MGND)
        Table 4. Text in Illustration
        *a

        Component without harness connected

        (Urea Pump)

        If the result is not as specified, replace the urea pump.