INSPECT DCU RELAY (DCU)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the DCU relay.
INSPECT EFI MAIN RELAY (EFI MAIN)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the EFI MAIN relay.
INSPECT EFI NO. 2 RELAY (EFI NO. 2)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the EFI NO. 2 relay.
INSPECT EDU RELAY (EDU)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the EDU relay.
INSPECT NOX RELAY (NOX)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the NOX relay.
INSPECT NO. 2 INTEGRATION RELAY
Note
The IG2 relay is built into the No. 2 integration relay.
Before performing the relay inspection for the relay of the No. 2 integration relay, inspect the IG2-MAIN fuse.
Inspect the IG2 relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.