AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST

Tech Tips

This is used only except 5L-E engine model.


  1. DATA LIST

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus:


      • Body / Air Conditioner / Data List.

      • Body / Combination Meter / Data List.

      • Powertrain / Engine and ECT / Data List.

    5. According to the display on the GTS, read the Data List.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Ambient Temp Sensor

      Cooler thermistor (ambient temperature sensor) /

      Min.: -23.3°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed

      Open in the circuit: -23.3°C (-9.94°F).

      Short in the circuit: 65.95°C (150.71°F).

      Adjusted Ambient Temp

      Adjusted ambient temperature /

      Min.: -30.8°C (-23.44°F)

      Max.: 50.8°C (123.44°F)

      Adjusted ambient temperature displayed -
      Evaporator Fin Thermistor

      No. 1 cooler thermistor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed

      Open in the circuit: -29.7°C (-21.46°F).

      Short in the circuit: 59.55°C (139.19°F).

      Evaporator Target Temp

      Target evaporator temperature /

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Target evaporator temperature displayed -
      Engine Coolant Temp

      Engine coolant temperature /

      Min.: 1.3°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Regulator Pressure Sensor

      Refrigerant pressure sensor /

      Min.: -0.4566 MPa

      Max.: 3.2943 MPa

      Actual refrigerant pressure displayed -
      Number of Trouble Codes Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs displayed -
      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Ambient Temperature Outside temperature / Min.: -40°C (-40°F), Max.: 87.5°C (189.5°F) Almost the same as actual outside temperature -
  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body / Air Conditioner / Active Test.

    5. According to the display on the GTS, perform the Active Test.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Magnetic Clutch Relay Magnet clutch relay operation ON or OFF -