AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE), Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to the system description for DTC P2714 Click here.

DTC No. DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

A003AN9E15

INSPECTION PROCEDURE

Note

Perform registration and/or initialization when parts related to the automatic transmission are replaced Click here.

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A003HR8E06
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      13 (SLT+) - 14 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      13 (SLT+) - Body ground Always 10 kΩ or higher
      14 (SLT-) - Body ground Always 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A003FZ6E06
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D116-15 (SLT+) - D116-14 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      D116-15 (SLT+) - Body ground Always 10 kΩ or higher
      D116-14 (SLT-) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SLT


    1. A003ETNE25
      Text in Illustration
      *1 Shift Solenoid Valve SLT

      Remove shift solenoid valve SLT Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

    NG
    OK