CANISTER INSPECTION


  1. INSPECT CHARCOAL CANISTER ASSEMBLY


    1. Check the appearance.


      1. Visually check the charcoal canister assembly for cracks or damage.

        If necessary, replace the charcoal canister assembly.

    2. Check the charcoal canister filter.


      1. A003F0XE02
        Text in Illustration
        *1 Charcoal Canister Filter
        *a Claw

        Detach the 2 claws and remove the charcoal canister filter.

      2. A003E5XE02
        Text in Illustration
        *1 Charcoal Canister Filter

        Visually check that the charcoal canister filter is not excessively damaged or dirty.

        If necessary, replace the charcoal canister assembly.

    3. Check the charcoal canister operation.


      1. A003EPYE02
        Text in Illustration
        *a Port A
        *b Port B
        *c Port C
        A003DCD Air

        Blow air (4.7 kPa (0.05 kgf/cm2, 0.7 psi)) into port A, then check that the air flows from ports B and C.

        If the ventilation is not as specified, replace the charcoal canister assembly.

    4. Clean the filter in canister.


      1. A003H7FE02
        Text in Illustration
        *a Port A
        *b Port B
        *c Port C
        A003DCD Air

        Clean the filter by blowing (19.6 kpa (0.2 kgf/cm2, 2.8 psi)) compressed air into port B while holding port A closed.

        Note


        • Do not attempt to wash the charcoal canister assembly.

        • No activated carbon should come out.

    5. Install the charcoal canister filter.