FUEL LID OPENER SWITCH INSPECTION

PROCEDURE


  1. INSPECT FUEL LID OPENER SWITCH


    1. A004R9SE01
      Text in Illustration
      *1

      Component without harness connected

      (Fuel Lid Opener Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 4 Switch pushed (On) Below 1 Ω
      1 - 4 Switch free (Off) 10 kΩ or higher

      If the result is not as specified, replace the fuel lid opener switch.