OCCUPANT DETECTION SENSOR INSPECTION

PROCEDURE


  1. INSPECT SEAT CUSHION COVER WITH PAD

    A004S72E01
    *1 More than 147 N of force applied

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 3 More than 147 N (15 kgf, 33.0 lbf) applied to occupant detection sensor Below 100 Ω

      If the result is not as specified, replace the seat cushion cover with pad.