GENERATOR INSTALLATION

PROCEDURE


  1. INSTALL GENERATOR ASSEMBLY


    1. A004P3CE02

      Using an E12 "TORX" socket wrench, install the generator assembly with the 2 bolts.

      Torque:
      38 N*m  { 387 kgf*cm, 28 ft.*lbf }

      Tech Tips

      Install the generator assembly with bolt A inserted as shown in the illustration.

    2. Connect the generator wire with the nut.

      Torque:
      13 N*m  { 129 kgf*cm, 9 ft.*lbf }
    3. Install the terminal cap.

    4. Connect the generator connector.

  2. INSTALL FAN AND GENERATOR V BELT

    Click here

  3. INSTALL REAR ENGINE UNDER COVER RH

    Click here

  4. INSTALL INTAKE MANIFOLD

    Click here

  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.