HAZARD WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    1. A004TLYE32
      Text in Illustration
      *1

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (TB) - 1 (E) Hazard warning signal switch off 10 kΩ or higher
      Hazard warning signal switch on Below 1 Ω
    2. Apply battery voltage to the connector and check the LED illumination condition.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 3 (ILL+)

      Battery negative (-) → Terminal 2 (ILL-)

      LED illuminates

      If the result is not as specified, there may be a malfunction in the hazard warning signal switch.