VALVE BODY ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT SHIFT SOLENOID VALVE SL

    A004Q2KE02
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SL)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve S4 connector

      • Battery negative (-) → Shift solenoid valve S4 body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE SLT

    A004QM7E68
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SLT)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE SLU

    A004QM7E68
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SLU)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  4. INSPECT SHIFT SOLENOID VALVE SL1

    A004QM7E68
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SL1)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  5. INSPECT SHIFT SOLENOID VALVE SL2

    A004QM7E68
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SL2)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  6. INSPECT SHIFT SOLENOID VALVE SL3

    A004QM7E68
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SL3)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  7. INSPECT SHIFT SOLENOID VALVE SL4

    A004QM7E68
    Text in Illustration
    *1

    Component without harness connected

    (Shift Solenoid Valve SL4)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.