PROCEDURE
INSTALL EXHAUST GAS TEMPERATURE SENSOR (for Upper Side)
Note
If the sensor is dropped, replace it with a new one.
Using a 14 mm union nut wrench, install the sensor.
Note
Use the formula to calculate special torque values for situations where a union nut wrench is combined with a torque wrench Click here.
Attach the sensor connector clamp.
INSTALL EXHAUST GAS TEMPERATURE SENSOR (for Lower Side)
Note
If the sensor is dropped, replace it with a new one.
| *1 | White Tube |
| *2 | Protective Tube |
Temporarily install the sensor with the union nut.
Attach the sensor connector clamp.
Temporarily install the clamp with the nut.
Note
Make sure the clamp is aligned with the white tube of the wire harness as shown in the illustration.
Tighten the nut.
Using a 14 mm union nut wrench, tighten the union nut of the sensor.
Note
When tightening the union nut, make sure that the protective tube of the sensor is within the range shown in the illustration.
Use the formula to calculate special torque values for situations where a union nut wrench is combined with a torque wrench Click here.
INSTALL EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY
INSTALL NO. 1 MANIFOLD CONVERTER INSULATOR
INSTALL ENGINE ASSEMBLY