FUEL PRESSURE DISCHARGE VALVE INSPECTION

PROCEDURE


  1. INSPECT PRESSURE DISCHARGE VALVE


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 3.42 to 3.78 Ω

      If the result is not as specified, replace the pressure discharge valve.