PROCEDURE
INSTALL ECM
Install the No. 2 ECM bracket to the ECM with the 2 screws.
Install the No. 1 ECM bracket to the ECM with the 2 screws.
Install the ECM with bracket with the 2 bolts.
Connect the 2 ECM connectors and lower the 2 levers.
Note
When connecting the ECM connector, make sure that dirt, water or other foreign matter is not stuck between the ECM connector and ECM.
Make sure that the 2 levers are securely lowered.
INSTALL NO. 2 AIR CLEANER INLET
Install the No. 2 air cleaner inlet with the bolt.
INSTALL NO. 1 AIR CLEANER INLET
Install the No. 1 air cleaner inlet with the clip.
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
Install the air cleaner cap sub-assembly to the air cleaner hose assembly and tighten the hose clamp.
Attach the 2 clamps.
Connect the mass air flow meter connector and attach the wire harness clamp.
INSTALL RADIATOR SUPPORT OPENING COVER
INSTALL NO. 1 ENGINE COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
PERFORM REGISTRATION
PERFORM INITIALIZATION