INTAKE AIR TEMPERATURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT INTAKE AIR TEMPERATURE SENSOR


    1. Partially immerse the sensor in water and warm up the water.

    2. Measure the resistance according to the value(s) in the table below.

      A004QA8E06
      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 2.21 to 2.65 kΩ
      1 - 2 60°C (140°F) 0.54 to 0.62 kΩ

      Note

      When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.

      If the result is not as specified, replace the intake air temperature sensor.