PROCEDURE
PRECAUTION
CAUTION:
Be sure to read the "PRECAUTION" thoroughly before servicing Click here.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE STEERING WHEEL ASSEMBLY
REMOVE LOWER STEERING COLUMN COVER
REMOVE UPPER STEERING COLUMN COVER
REMOVE SPIRAL WITH SENSOR CABLE SUB-ASSEMBLY
Note
Do not replace the spiral with sensor cable sub-assembly with the battery connected and the ignition switch ON.
Do not rotate the spiral with sensor cable sub-assembly with the battery connected and the ignition switch ON.
When rotating the spiral with sensor cable sub-assembly to check the operation of the sub-assembly (checking for abnormal noise, checking the Data List, etc.), make sure to perform the inspection with the steering wheel assembly installed.
Do not remove the steering angle sensor from the spiral cable.
| *1 | Slider |
|
Slide |
Slide the airbag connector slider as shown in the illustration and disconnect the airbag connector from the spiral with cable sensor sub-assembly.
Disconnect each connector from the spiral with sensor cable sub-assembly.
Detach the 3 claws and remove the spiral with sensor cable sub-assembly.