2WW BATTERY / CHARGING SERVICE DATA

Battery
Standard voltage Positive (+) terminal - Negative (-) terminal 12.5 to 12.9 V at 20 °C(68 °F)
Fuse
Standard resistance Below 1 Ω
Charging circuit without load
Standard current 10 A or less
Standard voltage

12.1 to 15.4 V

(when engine speed at 2000 rpm)

Charging circuit with load
Standard current 30 A or higher
Charging control system (w/ Entry and start system)
Tester Connection Condition Specified Condition
D113-1 (LIN1) - B106-1 (LIN) Always Below 1 Ω
D113-1 (LIN1) or B106-1 (LIN) - Body ground and other terminals Ignition switch off (while LIN communication is stopped) 10 kΩ or higher
Charging control system (w/o Entry and start system)
Tester Connection Condition Specified Condition
D112-17 (LIN1) - B106-1 (LIN) Always Below 1 Ω
D112-17 (LIN1) or B106-1 (LIN) - Body ground and other terminals Ignition switch off (while LIN communication is stopped) 10 kΩ or higher
Generator brush holder assembly
Brush length Standard exposed length 11.2 mm (0.441 in.)
Minimum exposed length 2.0 mm (0.0787 in.)