2WW COOLING
SERVICE DATA
Thermostat
Condition
Specified Condition
Standard value opening temperature
100°C (212°F)
Cooling Fan Motor
Item
Condition
Specified Condition
Cooling fan motor
Motor is turning at 20°C (68°F) when battery is 12 V
12.2 to 15.7 A
No. 2 cooling fan motor
Motor is turning at 20°C (68°F) when battery is 12 V
12.2 to 15.7 A
Radiator
Item
Condition
Specified Condition
Reservoir cap
Standard value (for brand new cap)
126 to 143 kPa (1.3 to 1.5 kgf/cm2, 18.2 to 20.7 psi)
Minimum standard value (after using cap)
101 kPa (1.0 kgf/cm2, 14.6 psi)