2AD-FTV COOLING SERVICE DATA

Thermostat
Condition Specified Condition
Standard value opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)
Cooling Fan Motor
Item Condition Specified Condition
No. 1 cooling fan motor While the motor is turning at 20°C (68°F) when battery is 12 V 12.2 to 15.7 A
No. 2 cooling fan motor While the motor is turning at 20°C (68°F) when battery is 12 V 7.4 to 10.9 A
Cooling Fan Relay
Item Tester Connection Specified Condition
No. 1 fan relay 3 - 5 Standard resistance: 10 kΩ or higher
3 - 5 Standard resistance: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)
No. 2 fan relay 3 - 4 Standard resistance: Below 1 Ω
3 - 5 Standard resistance: 10 kΩ or higher
3 - 4 Standard resistance: 10 kΩ or higher (When battery voltage is applied to terminals 1 and 2)
3 - 5 Standard resistance: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)
No. 3 fan relay 3 - 5 Standard resistance: 10 kΩ or higher
3 - 5 Standard resistance: Below 1 Ω (When battery voltage is applied to terminals 1 and 2)
Radiator Cap
Item Condition Specified Condition
Radiator reservoir cap Standard valve (for brand new cap)

93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to psi)

Minimum standard value (after using cap)

79 kPa (0.8 kgf/cm2, 11.4 psi)