| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Glow plug terminal - Body ground | 20°C (68°F) | 0.1 to 0.9 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) terminal - Terminal 30 - Terminal 50 | 11 V | 70 A or less |
| Starter armature assembly | Segments | 2.67 to 3.29 Ω |
| Segment - Coil core | 10 kΩ or higher | |
| Standard circle runout | 0.05 mm (0.00197 in.) | |
| Maximum circle runout | 0.07 mm (0.00276 in.) | |
| Standard commutator diameter | 30.2 mm (1.19 in.) | |
| Minimum commutator diameter | 28.9 mm (1.14 in.) | |
| Standard undercut depth | 1.43 mm (0.0563 in.) | |
| Minimum undercut depth | 0.75 mm (0.0295 in.) | |
| Brush | Standard length | 12.3 mm (0.484 in.) |
| Minimum length | 9.8 mm (0.386 in.) | |
| Tester connection A-B | 10 kΩ or higher | |
| Tester connection A-C | 10 kΩ or higher | |
| Tester connection A-D | Below 1 Ω | |
| Tester connection B-C | Below 1 Ω | |
| Tester connection B-D | 10 kΩ or higher | |
| Tester connection C-D | 10 kΩ or higher | |
| Magnet starter switch assembly | Terminal 50 - Terminal C | Below 1 Ω |
| Terminal 50 - Body | Below 2 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 7 (SS1) - 5 (GND) | Pushed | Below 1 Ω |
| 2 (SS2) - 5 (GND) | Pushed | Below 1 Ω |
| 7 (SS1) - 5 (GND) | Not pushed | 10 kΩ or higher |
| 2 (SS2) - 5 (GND) | Not pushed | 10 kΩ or higher |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| All combinations of all terminals | LOCK | 10 kΩ or higher |
| 2 (AM1) - 3 (ACC) | ACC | Below 1 Ω |
| 2 (AM1) - 3 (ACC) 2 (AM1) - 4(IG1) 6 (IG2) - 7 (AM2) |
ON | Below 1 Ω |
| 1 (ST1) - 2 (AM1) 1 (ST1) - 4 (IG1) 6 (IG2) - 7 (AM2) 6 (IG2) - 8 (ST2) |
START | Below 1 Ω |
| Starter relay | Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher | |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| ACC relay | Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher | |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| GLOW relay | Tester Connection | Condition | Specified Condition |
| 1 - 2 | Battery voltage not applied to terminals 3 and 4 | 10 kΩ or higher | |
| Battery voltage applied to terminals 3 and 4 | Below 1 Ω |