CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Disconnect the D101 air conditioning amplifier connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| D101-1 (IG+) - D101-14 (GND) | Y - W-B | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| D101-13 (SG-2) - Body ground | V - Body ground | Ground for air conditioning pressure sensor | Always | Below 1 Ω |
| D101-14 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 Ω |
| D101-21 (B) - D101-14 (GND) | R - W-B | Battery power source | Always | 11 to 14 V |
Reconnect the D101 air conditioning amplifier connector.
Measure the resistance, voltage and waveform according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| D101-2 (SOL+) - D101-14 (GND)*2 | LG - W-B | Compressor with pulley assembly operation signal |
|
Pulse generation (see waveform 2) |
| D101-3 (PTC2) - Body ground*1 | B - Body ground | HTR SUB NO.2 relay operation signal |
|
11 to 14 V*3 |
|
Below 1 V*3 | |||
| D101-9 (PRE) - D101-13 (SG-2)*2 | G - V | Air conditioning pressure sensor signal |
|
0.70 to 4.69 V |
|
Below 0.70 V | |||
|
4.69 V or higher | |||
| D101-10 (S5-3) - D101-13 (SG-2)*2 | B - V | Power supply for air conditioning pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| D101-22 (BLW) - D101-14 (GND) | G - W-B | Blower motor control signal |
|
Pulse generation (see waveform 1) |
| D101-27 (HLS) - D101-14 (GND)*1 | B - W-B | Headlight signal (PTC Heater control) |
|
11 to 14 V |
|
Below 1 V | |||
| D101-39 (PTC3) - Body ground*1 | BR - Body ground | HTR SUB NO.3 relay operation signal |
|
11 to 14 V*3 |
|
Below 1 V*3 | |||
| D101-40 (PTC1) - Body ground*1 | W - Body ground | HTR SUB NO.1 relay operation signal |
|
11 to 14 V*3 |
|
Below 1 V*3 | |||
| z3-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 Ω |
| z3-3 (BUS) - z3-2 (BUS G) | - | BUS IC control signal | Ignition switch ON | Pulse generation |
| z3-4 (B BUS) - z3-2 (BUS G) | - | Power supply for BUS IC | Always | 11 to 14 V |
| z3-5 (SGA) - Body ground*2 | - | Ground for evaporator temperature sensor | Always | Below 1 Ω |
| z3-6 (TEA) - z3-5 (SGA)*2 | - | Evaporator temperature sensor signal |
|
1.7 to 2.1 V |
|
0.9 to 1.3 V |
*1: w/ PTC Heater
*2: w/ Cooler
Tech Tips
*3: After the measurement conditions are met, wait 30 seconds before performing measurements.
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | D101-22 (BLW) - D101-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Condition | Ignition switch ON Blower switch LO |
Tech Tips
When the blower level is increased, the duty ratio changes accordingly.
Using an oscilloscope, check waveform 2.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | D101-2 (SOL+) - D101-14 (GND) |
| Tool Setting | 5 V/DIV., 500 μs/DIV. |
| Condition | Engine running A/C switch on Blower switch LO |
CHECK AIR CONDITIONING CONTROL ASSEMBLY
Disconnect the D12 control connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| D12-5 (IG+) - D12-11 (GND) | G - BR | IG power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| D12-11 (GND) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
CHECK MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the DB, DE, DG and D80 ECU connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| DE-17 (GND1) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| D80-4 (GND2) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| DB-12 (BECU) - Body ground | W - Body ground | Power source | Always | 11 to 14 V |
| DG-1 (ALTB) - Body ground | W - Body ground | Power source | Always | 11 to 14 V |