GENERATOR REMOVAL

PROCEDURE


  1. REMOVE RADIATOR SUPPORT OPENING COVER

    Click here

  2. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

  3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  4. REMOVE REAR ENGINE UNDER COVER RH

    Click here

  5. REMOVE NO. 2 CYLINDER HEAD COVER

    Click here

  6. REMOVE V-RIBBED BELT

    Click here

  7. REMOVE GENERATOR ASSEMBLY


    1. A00578P

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the connector and detach the wire harness clamp.

    4. A00581Q

      Remove the 2 bolts and adjusting bar.

    5. A0053JH

      Remove the bolt and generator.

    6. A00530H

      Remove the bolt and wire harness clamp bracket.