VACUUM PUMP(for 3ZR-FAE) INSPECTION

PROCEDURE


  1. INSPECT VACUUM PUMP VANE


    1. A00536KE03
      Text in Illustration
      *1 Vacuum Pump Vane Cap
      *2 Vacuum Pump Vane

      Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out.

      Tech Tips

      If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones.

    2. A0055D2E03

      Using a micrometer, measure length A of the vacuum pump vane with the vacuum pump vane caps removed.

      Minimum
      23.8 mm (0.937 in.)

      Tech Tips

      If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.

      Note

      Measure the length 10 mm (0.394 in.) in from each end of the vacuum pump vane.

    3. A0054YPE06
      Text in Illustration
      *1 Vacuum Pump Vane
      *2 Vacuum Vane Cap

      Using a vernier caliper, measure length B of the vacuum pump vane with the vacuum pump vane caps installed.

      Minimum
      76.0 mm (3.00 in.)

      Tech Tips

      If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.

      Note

      Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.

  2. INSPECT VACUUM PUMP HOUSING


    1. A005416

      Check that the rotor part, coupling, vacuum pump housing or vacuum end cover is not damaged or excessively worn out.

      Tech Tips