DESCRIPTION
Refer to "SRS Warning Light Remains ON" Click here.
WIRING DIAGRAM
Refer to "SRS Warning Light Remains ON" Click here.
CAUTION / NOTICE / HINT
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Click here.
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected Click here.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK BATTERY
Measure the voltage of the battery.
| Standard voltage |
|---|
| 11 to 14 V |
| NG |
|
REPLACE OR RECHARGE BATTERY |
| OK |
|
CHECK CONNECTION OF CONNECTORS
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the combination meter assembly.
| OK |
|---|
| The connectors are properly connected. |
| NG |
|
CONNECT CONNECTORS PROPERLY |
| OK |
|
CHECK HARNESS AND CONNECTOR (SOURCE VOLTAGE OF COMBINATION METER ASSEMBLY)
| *a | Front view of wire harness connector (to Combination Meter Assembly) |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the D66 connector from the combination meter assembly.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK SRS WARNING LIGHT (SHORT TO GROUND)
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the connector to the combination meter assembly.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Check the SRS warning light condition.
| OK |
|---|
| After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on. |
Tech Tips
The primary check period is approximately 6 seconds after the ignition switch is turned to ON.
| OK |
|
REPLACE AIRBAG SENSOR ASSEMBLY Click here |
| NG |
|
GO TO METER / GAUGE SYSTEM Click here |