| DTC Code | DTC Name |
|---|---|
| P264A | "A" Rocker Arm Actuator Position Sensor Circuit Bank 1 |
DESCRIPTION
There are position sensor and angle sensor in the continuously variable valve lift controller assembly. They detect the actuator position and rotation direction. When there is a malfunction in any of the sensors, a DTC is stored and the MIL illuminates.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P264A | When either of the following conditions is met (1 trip detection logic):
|
Continuously variable valve lift controller assembly |
CAUTION / NOTICE / HINT
Note
When one of the following DTCs is output and the MIL is illuminated, actuator position learning is performed during the next trip. After the system returns to normal, actuator position learning is performed during the next trip and the MIL remains illuminated until learning is complete.
| Actuator position learning is performed when these DTCs are output. |
|---|
| P1049, P104A, P1055, P2646, P2647, P2648, P2649, P264A, U011B |
Tech Tips
After performing repairs, perform the following procedures and check that DTCs are not output again.
Connect the GTS to the DLC3.
Start the engine and warm it up.
Turn the GTS on.
Clear the DTCs Click here.
Turn the ignition switch off and wait 10 seconds.
Start the engine and idle it for 20 seconds.
Clear the DTCs Click here.
Turn the ignition switch off and wait 10 seconds.
Start the engine and idle it for 20 seconds.
Turn the ignition switch off and wait 10 seconds.
Turn the ignition switch to ON.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
After using the GTS to perform minimum valve lift learning, keep the engine idling for 30 seconds to complete learning. Otherwise, the VALVEMATIC system may not operate normally, causing poor acceleration, etc.
PROCEDURE
REPLACE CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER ASSEMBLY
Replace the continuously variable valve lift controller assembly Click here.
Tech Tips
Perform "Inspection After Repair" after replacing the continuously variable valve lift controller assembly Click here.
| NEXT |
|
END |