CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P2822

DTC Code DTC Name
P2822 Pressure Control Solenoid "J" Electrical (Shift Solenoid Valve SLP)

DESCRIPTION

According to current control by the ECM, the shift solenoid valve SLP controls primary pulley pressure in accordance with the requested gear ratio to perform gear ratio changes.

A0059G2E04
Text in Illustration
*1 Spool Valve *2 Sleeve
*3 Solenoid Coil - -
*a Hydraulic Pressure *b Current Flow to Solenoid
DTC No.

DTC Detection Condition


  1. Diagnosis Condition

  2. Malfunction Status

  3. Malfunction Time

  4. Other

Trouble Area
P2822
  1. The vehicle is being driven.

  2. An open or short in the shift solenoid valve SLP circuit is detected.

  3. 1 second or more

  4. 1-trip detection logic


  • Harness or connector

  • Continuously variable transaxle assembly (Shift solenoid valve SLP)

  • ECM

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SLP circuit. If there is an open or short in the shift solenoid valve SLP circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.

WIRING DIAGRAM

A0053BXE03
*a Shift Solenoid Valve SLP
*b Continuously Variable Transaxle Assembly (Transmission Wire)

CAUTION / NOTICE / HINT

Note


  • Perform initialization when parts related to the continuously variable transaxle are replaced Click here.

  • Check that no DTCs are stored after performing initialization Click here.

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLP)


    1. A0054F3E12
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 (SLP+) - 9 (SLP-) 20°C (68°F) 5.0 to 5.6 Ω
      3 (SLP+) - Body ground and other terminals Always 10 kΩ or higher
      9 (SLP-) - Body ground and other terminals Always 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A00548CE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B53-39 (SLP+) - B53-38 (SLP-) 20°C (68°F) 5.0 to 5.6 Ω
      B53-39 (SLP+) - Body ground and other terminals Always 10 kΩ or higher
      B53-38 (SLP-) - Body ground and other terminals Always 10 kΩ or higher

    NG
    OK
  3. REPLACE ECM


    1. Replace the ECM Click here.


    NEXT
  4. REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY


    1. Replace the continuously variable transaxle assembly Click here.


    NEXT