KNOCK SENSOR INSTALLATION

PROCEDURE


  1. INSTALL KNOCK SENSOR


    1. A0059HXE01
      *1 Top

      Install the knock sensor with the bolt.

      Torque:
      21 N*m  { 214 kgf*cm, 15 ft.*lbf }

      Note

      Make sure that the knock sensor is in the correct position.

    2. A005576

      Connect the knock sensor connector.

  2. INSTALL INTAKE MANIFOLD


    1. Install the intake manifold Click here.