SFI SYSTEM, Diagnostic DTC:P0112, P0113

DTC Code DTC Name
P0112 Intake Air Temperature Circuit Low Input
P0113 Intake Air Temperature Circuit High Input

DESCRIPTION

A00586SE08
Fig. 1
*1 Resistance
*2 Acceptable
*3 Temperature

DTC No. DTC Detection Condition Trouble Area
P0112

Short in intake air temperature sensor circuit for 0.5 seconds

(1 trip detection logic)


  • Short in intake air temperature sensor circuit


  • Intake air temperature sensor (built into mass air flow meter)


  • ECM

P0113

Open in intake air temperature sensor circuit for 0.5 seconds

(1 trip detection logic)


  • Open in intake air temperature sensor circuit


  • Intake air temperature sensor (built into mass air flow meter)


  • ECM

Tech Tips

When any of these DTCs are output, check the intake air temperature by entering the following menus on the intelligent tester: Powertrain / Engine and ECT / Data List / Intake Air.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
140°C (284°F) or higher Short circuit

WIRING DIAGRAM

A0054PUE18
*a Intake Air Temperature Sensor (Built into MAF Meter)

CAUTION / NOTICE / HINT

Tech Tips

Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON and turn the tester on.

    3. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

    4. Read the value displayed on the tester.

      Standard
      Same as actual intake air temperature.
      Result
      Result Proceed to
      Temperature displayed is -40°C (-40°F) A
      Temperature displayed is 140°C (284°F) or higher B
      Temperature displayed same as actual intake air temperature C

      Tech Tips


      • If there is an open circuit, the intelligent tester indicates -40°C (-40°F).


      • If there is a short circuit, the intelligent tester indicates 140°C (284°F) or higher.


    B
    C
    A
  2. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS)


    1. A0053MLE03
      Text in Illustration
      *1 Mass Air Flow Meter
      *2 ECM
      *3

      Front view of wire harness connector

      (to Mass Air Flow Meter)

      Confirm good connection at the mass air flow meter.

    2. Disconnect the mass air flow meter connector.

    3. Connect terminals THA and ETHA of the MAF meter wire harness side connector.

    4. Connect the intelligent tester to the DLC3.

    5. Turn the ignition switch to ON and turn the tester on.

    6. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

    7. Read the value displayed on the tester.

      Standard
      140°C (284°F) or higher.
    8. Reconnect the mass air flow meter connector.


    OK
    NG
  3. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    1. Disconnect the mass air flow meter connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B2-1 (THA) - B39-87 (THA) Always Below 1 Ω
      B2-2 (E2) - B39-88 (ETHA) Always Below 1 Ω
    4. Reconnect the mass air flow meter connector.

    5. Reconnect the ECM connector.


    OK
    NG
  4. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS)


    1. A0056AYE21
      Text in Illustration
      *1 Mass Air Flow Meter
      *2 ECM

      Disconnect the mass air flow meter connector.

    2. Connect the intelligent tester to the DLC3.

    3. Turn the ignition switch to ON and turn the tester on.

    4. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

    5. Read the value displayed on the tester.

      Standard
      -40°C (-40°F)
    6. Reconnect the mass air flow meter connector.


    OK
    NG
  5. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    1. Disconnect the mass air flow meter connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B2-1 (THA) or B39-87 (THA) - Body ground Always 10 kΩ or higher
    4. Reconnect the mass air flow meter connector.

    5. Reconnect the ECM connector.


    OK
    NG