3ZR-FAE INTAKE / EXHAUST SERVICE DATA

Vacuum switching valve (for ACIS)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 27 to 33 Ω

1 - Body ground

2 - Body ground

Always 1 MΩ or higher
Exhaust manifold / Exhaust pipe

Compression spring

(Front exhaust pipe assembly x Exhaust manifold)

Minimum length:

41.5 mm (1.63 in.)

Compression spring

(Tailpipe assembly x Front exhaust pipe assembly)

Minimum length:

38.5 mm (1.52 in.)