PROCEDURE
INSTALL FLOOR SHIFT LEVER ASSEMBLY
Attach the 2 claws to connect the shift control cable and select control cable to the shift lever assembly.
Connect the end of the shift control cable to the shift lever assembly and install the clip.
Install the shift lever assembly with the 4 bolts.
Attach the 3 wire harness clamps.
Release the lock of the cable length adjustment structure of the select cable.
| *1 | Twist |
| *2 | Stopper |
Twist the stopper.
| *1 | Pull out |
| *2 | Lock Piece |
| *3 | Case |
Pull the lock piece outward from the case to release the lock.
| *1 | Reverse Restrict Pin Assembly |
| *2 | Outer Lever |
w/ Reverse Restrict Pin Assembly:
Hook the outer lever of the manual transaxle onto the reverse restrict pin assembly to secure it.
| *1 | Outer Lever |
| *a | Installation hole for transmission control select cable adjustment |
| *b | Cutout |
w/o Reverse Restrict Pin Assembly:
Align the outer lever cutout with the hole for adjusting the transmission control select cable, and insert the bolt by hand to secure the outer lever as shown in the illustration.
Note
In order to avoid case damage, do not push the bolt in forcefully.
Tech Tips
Use a bolt with a diameter of 6.0 mm (0.236 in.) and a length of at least 18 mm (0.709 in.) or more.
Depending on the actual bolt diameter, it may be difficult to insert the bolt. In that case, as there is some variation in actual bolt diameters, use a 6.0 mm (0.236 in.) bolt with a comparatively small diameter.
Connect the end of the select control cable to the shift lever assembly and install the clip.
Note
Make sure the lock piece of the select control cable is facing upward when the select control cable is connected.
Make sure the clip is inserted in the direction shown in the illustration.
| *1 | Slider |
| *2 | Inhibitor Wall |
Push the slider against the inhibitor wall.
Note
Do not pull up the slider.
When adjusting the cable, make sure that the shift lever is not in 1 or 2.
Lock the cable length adjustment structure of the select cable.
| *1 | Push |
| *2 | Lock Piece |
| *3 | Case |
Push the lock piece into the case with slider held against the inhibitor wall.
| *1 | Return |
| *2 | Stopper |
Return the stopper to prevent the lock from being released.
Note
Push in the lock piece completely.
Make sure that the cable length adjustment structure is locked securely.
| *1 | Reverse Restrict Pin Assembly |
| *2 | Outer Lever |
| *a | Release |
w/ Reverse Restrict Pin Assembly:
Move the shift lever to R to release the outer lever.
w/o Reverse Restrict Pin Assembly:
Pull out the bolt to free the outer lever.
INSTALL CONSOLE BOX ASSEMBLY