PROCEDURE
ADJUST TRANSMISSION CONTROL SELECT CABLE
Tech Tips
After the shift lever or the shift cable is replaced, be sure to adjust the transmission control cable assembly.
If the shift lever does not move (or the shift lever is difficult to move) to 1st or 2nd or if it is possible to move the shift lever to reverse without pulling up the slider shaft, the length of the cable must be adjusted.
Disconnect the select control cable from the shift lever assembly Click here.
Release the lock of the cable length adjustment structure of the select cable.
| *1 | Twist |
| *2 | Stopper |
Twist the stopper.
| *1 | Pull out |
| *2 | Lock Piece |
| *3 | Case |
Pull the lock piece outward from the case to release the lock.
| *1 | Outer Lever |
| *a | Installation hole for transmission control select cable adjustment |
| *b | Cutout |
Align the outer lever cutout with the hole for adjusting the transmission control select cable, and insert the bolt by hand to secure the outer lever as shown in the illustration.
Note
In order to avoid case damage, do not push the bolt in forcefully.
Tech Tips
Use a bolt with a diameter of 6.0 mm (0.236 in.) and a length of at least 18 mm (0.709 in.) or more.
Depending on the actual bolt diameter, it may be difficult to insert the bolt. In that case, as there is some variation in actual bolt diameters, use a 6.0 mm (0.236 in.) bolt with a comparatively small diameter.
Connect the select control cable to the shift lever assembly Click here.
| *1 | Slider |
| *2 | Inhibitor Wall |
Push the slider against the inhibitor wall.
Note
Do not pull up the slider.
When adjusting the cable, make sure that the shift lever is not in 1 or 2.
Lock the cable length adjustment structure of the select cable.
| *1 | Push |
| *2 | Lock Piece |
| *3 | Case |
Push the lock piece into the case with the slider held against the inhibitor wall.
| *1 | Return |
| *2 | Stopper |
Return the stopper to prevent the lock from being released.
Note
Push in the lock piece completely.
Make sure that the cable length adjustment structure is locked securely.
Pull out the bolt to free the outer lever.