TRANSMISSION CONTROL CABLE INSTALLATION

PROCEDURE


  1. INSTALL TRANSMISSION CONTROL CABLE ASSEMBLY


    1. B0040LO

      Install the control cable assembly through the floor hole.

    2. Attach the 2 claws to connect the shift control cable and select control cable to the floor shift lever assembly.

    3. B0040G6

      Attach the grommet of the control cable assembly with the 2 nuts.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    4. B0040HU

      Connect the end of the shift control cable to the shift lever assembly and install the clip.

    5. B0040OB

      Attach the bracket of the control cable assembly with the bolt.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    6. A00550A

      Connect the 2 cables to the control cable bracket with 2 new clips.

    7. A0057AB

      Connect the 2 cables to the transaxle and install the 2 clips.

    8. Release the lock of the cable length adjustment structure of the select cable.


      1. B0040HXE01
        *1 Twist
        *2 Stopper

        Twist the stopper.

      2. B0040IFE04
        *1 Pull out
        *2 Lock Piece
        *3 Case

        Pull the lock piece outward from the case to release the lock.

    9. B0040NUE05
      Text in Illustration
      *1 Select Outer Lever
      *2 Hole

      Align the hole of the select outer lever with the hole in the transaxle case.

    10. A0058NO

      Insert a bolt into the aligned holes to fix the select outer lever in place.

      Note

      Do not push in the bolt forcefully or damage the transaxle case.

      Tech Tips


      • Use a bolt with a diameter of 6 mm (0.236 in.) and a length of at least 16 mm (0.630 in.).

      • Depending on the bolt diameter, it may be difficult to insert the bolt. In that case, use a bolt with a diameter smaller than 6 mm (0.236 in.).

    11. B0040MV

      Connect the end of the select control cable to the shift lever assembly and install the clip.

      Note


      • Make sure the lock piece of the select control cable is facing upward when the select control cable is connected.

      • Make sure the clip is inserted in the direction shown in the illustration.

    12. B0040G0E02
      Text in Illustration
      *1 Slider
      *2 Inhibitor Wall

      Push the slider against the inhibitor wall.

      Note


      • Do not pull up the slider.

      • When adjusting the cable, make sure that the shift lever is not in 1 or 2.

    13. Lock the cable length adjustment structure of the select cable.


      1. B0040H8E03
        *1 Push
        *2 Lock Piece
        *3 Case

        Push the lock piece into the case with the slider held against the inhibitor wall.

      2. B0040OUE01
        *1 Return
        *2 Stopper

        Return the stopper to prevent the lock from being released.

        Note


        • Push in the lock piece completely.

        • Make sure that the cable length adjustment structure is locked securely.

    14. A00581W

      Remove the bolt to free the select outer lever.

  2. INSTALL FRONT NO. 1 FLOOR HEAT INSULATOR

    B0040FK

    1. Install the front No. 1 floor heat insulator with the 3 nuts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }
  3. INSTALL CONSOLE BOX ASSEMBLY

    Click here

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  5. INSTALL AIR CLEANER CAP SUB-ASSEMBLY

    Click here

  6. INSTALL NO. 2 CYLINDER HEAD COVER

    Click here

  7. INSTALL FRONT EXHAUST PIPE ASSEMBLY

    Click here