DESCRIPTION
The air conditioning amplifier assembly detects the temperature of the area near the windshield glass using this circuit. The air conditioning amplifier assembly applies voltage to the air conditioning thermistor assembly (glass surroundings temperature sensor). As the temperature of the area near the windshield glass rises, the resistance decreases. The air conditioning amplifier assembly detects the resistance change as the windshield glass surroundings temperature changes.
The glass surroundings temperature sensor is integrated with the air conditioning thermistor assembly.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B14A9 | Open or short in glass surroundings temperature sensor circuit |
|
Tech Tips
The whole air conditioning thermistor assembly should be replaced if the glass surroundings temperature sensor is malfunctioning.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING TECHSTREAM
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Glass Surroundings Temperature | Glass surroundings temperature/ Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual glass surroundings temperature displayed | - |
| OK |
|---|
| The display is as specified in the Normal Condition column. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| A |
|
INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS SURROUNDINGS TEMPERATURE SENSOR)
| *a | Component without harness connected (Air Conditioning Thermistor Assembly (Glass Surroundings Temperature Sensor)) |
| *b | Heat Conduction Sheet Part |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
Remove the air conditioning thermistor assembly (glass surroundings temperature sensor) Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
| NG |
|
REPLACE AIR CONDITIONING THERMISTOR ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - GLASS SURROUNDINGS TEMPERATURE SENSOR)
Disconnect the I77 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here