LIGHTING SYSTEM Luggage Compartment Door Courtesy Switch Circuit

DESCRIPTION

The main body ECU (multiplex network body ECU) detects the condition of the luggage compartment door lock assembly using this circuit.

WIRING DIAGRAM

A01HTLQE04

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING TECHSTREAM


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the Techstream on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. Read the display on the Techstream.

      Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Luggage Courtesy SW Luggage compartment door courtesy switch signal/ON or OFF

      ON: Luggage compartment door open

      OFF: Luggage compartment door closed

      -
      OK
      Normal conditions listed above are displayed.

    NG
    OK
  2. INSPECT LUGGAGE COMPARTMENT DOOR LOCK ASSEMBLY


    1. Remove the luggage compartment door lock assembly Click here.

    2. Inspect the luggage compartment door lock assembly Click here.

      OK
      Luggage compartment door lock assembly is normal.

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (LUGGAGE COMPARTMENT DOOR LOCK ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)


    1. Disconnect the 3C instrument panel junction block assembly connector.

    2. Disconnect the T3 luggage compartment door lock assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T3-3 (D+) - 3C-9 Always Below 1 Ω
      T3-3 (D+) - Body ground Always 10 kΩ or higher
      T3-2 (E) - Body ground Always Below 1 Ω

    NG
    OK
  4. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly Click here.

    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

    3. Measure the resistance according to the value(s) in the table below.

      A01HSKYE09
      Text in Illustration
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      3C-9 - MB-4 (LGCY) Always Below 1 Ω

    NG
    OK