DESCRIPTION
When the blind spot monitor main switch (warning canceling switch assembly) is turned on, a signal is sent to the blind spot monitor sensor RH and the blind spot monitor indicator on the blind spot monitor main switch (warning canceling switch assembly) illuminates. The blind spot monitor system operates according to this signal.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)
Check that the blind spot monitor indicator on the blind spot monitor main switch (warning canceling switch assembly) illuminates normally when the blind spot monitor main switch (warning canceling switch assembly) is turned from off to on.
Check that the blind spot monitor indicator on the blind spot monitor main switch (warning canceling switch assembly) turns off normally when the blind spot monitor main switch (warning canceling switch assembly) is turned from on to off.
| OK |
|---|
| The blind spot monitor indicator operates normally. |
| NG |
|
READ VALUE USING TECHSTREAM Click here |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
READ VALUE USING TECHSTREAM
Connect the Techstream to the DLC3.
Turn the power switch to on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master / Data list.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Main Switch | Blind spot monitor main switch (warning canceling switch assembly) / ON or OFF | ON: Blind spot monitor main switch (warning canceling switch assembly) on OFF: Blind spot monitor main switch (warning canceling switch assembly) off |
- |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY) Click here |
| A |
|
INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)
Remove the blind spot monitor main switch (warning canceling switch assembly) Click here.
| *a | Component without harness connected (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - AUXILIARY BATTERY)
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BLIND SPOT MONITOR SENSOR RH)
Disconnect the O28 blind spot monitor sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE BLIND SPOT MONITOR SENSOR RH Click here
INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)
Remove the blind spot monitor main switch (warning canceling switch assembly) Click here.
| *a | Component without harness connected (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly)) |
Apply auxiliary battery voltage to the blind spot monitor main switch (warning canceling switch assembly) connector and check the operation of the blind spot monitor indicator, as shown in the table below.
| OK | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BLIND SPOT MONITOR SENSOR RH)
Disconnect the O28 blind spot monitor sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE BLIND SPOT MONITOR SENSOR RH Click here