INVERTER WITH CONVERTER REMOVAL


  1. PRECAUTION

    Click here

  2. REMOVE SERVICE PLUG GRIP

    Click here

  3. DRAIN COOLANT (for Inverter)

    Note


    • Do not reuse the drained coolant because it may contain foreign objects.

    • Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.


    1. Remove the reserve tank cap.

      CAUTION:

      To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.

    2. A01HVNF

      Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.

      CAUTION:

      Use caution when handling coolant immediately after driving or in summer because it may be hot.

    3. Install the plug with a new gasket.

      Torque:
      39 N*m  { 397 kgf*cm, 29 ft.*lbf }
  4. REMOVE CONNECTOR COVER ASSEMBLY

    CAUTION:


    • Do not touch the high voltage connectors and terminals for 10 minutes after the service plug grip is removed.

    • Wear insulated gloves.

    Note

    Do not start the hybrid system with the service plug grip removed because it may cause a malfunction.


    1. A01HTFV

      Remove the 2 bolts and connector cover assembly.

      Note


      • Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  5. CHECK TERMINAL VOLTAGE

    CAUTION:

    Wear insulated gloves.

    Note

    Do not allow any foreign matter or water to enter the inverter with converter assembly.


    1. A01HSVH

      Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

      Standard voltage
      0 V

      Tech Tips

      Use a measuring range of DC 750 V or more on the voltmeter.

  6. TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01HUVW

      Temporarily install the connector cover assembly with the bolt to prevent any foreign matter or water from entering the inverter with converter assembly.

  7. REMOVE COOL AIR INTAKE DUCT SEAL


    1. A01HV5R

      Remove the 7 clips and cool air intake duct seal.

  8. REMOVE INLET AIR CLEANER ASSEMBLY


    1. A01HSG6

      Remove the 2 bolts and inlet air cleaner assembly.

  9. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    1. A01HTQ5

      Disconnect the mass air flow meter connector and wire harness clamp from the air cleaner cap sub-assembly.

    2. Disconnect the ventilation hose from the cylinder head cover.

    3. Disconnect the connector and wire harness clamp.

    4. A01HSY1

      Release the 2 clamps and remove the air cleaner cap sub-assembly.

    5. A01HVCDE01
      Text in Illustration
      *1 Retainer
      *2 Fuel Tube Connector
      *3 Pipe
      *4 O-ring
      *a Pinch
      *b Pull

      Disconnect the 2 fuel vapor feed hoses.

      Note


      • Remove any dirt or foreign matter on the fuel tube connector before performing this work.

      • Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the fuel tube connector has an O-ring that seals the pipe.

      • Perform this work by hand. Do not use any tools.

      • Protect the disconnected parts by covering them with plastic bags after disconnecting each fuel vapor feed hose.

    6. A01HVR4

      Loosen the hose clamp and disconnect the air cleaner hose from the throttle with motor body assembly.

  10. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  11. REMOVE AIR CLEANER CASE SUB-ASSEMBLY


    1. A01HSNXE03
      Text in Illustration
      *a Projection

      Remove the 2 bolts and air cleaner case sub-assembly.

  12. REMOVE NO. 5 INVERTER BRACKET


    1. A01HV2L

      Remove the 2 bolts and No. 5 inverter bracket.

  13. REMOVE NO. 4 INVERTER BRACKET


    1. A01HSPR

      Remove the 3 bolts and No. 4 inverter bracket.

  14. REMOVE UPPER INVERTER COVER

    CAUTION:

    Wear insulated gloves.


    1. A01HVOM

      Remove the 2 bolts and upper inverter cover (generator cable side).

      Note


      • Make sure to pull the upper inverter cover straight up, as a connector is connected to the bottom of the cover.

      • Do not touch the upper inverter cover waterproofing rubber.

  15. DISCONNECT GENERATOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. A01HTVL

      Using an insulated tool, remove the 3 bolts.

    2. A01HSZ2

      Disconnect the 2 wire harness clamps and separate the generator cable.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  16. REMOVE UPPER INVERTER COVER

    CAUTION:

    Wear insulated gloves.


    1. A01HV1K

      Remove the 2 bolts and upper inverter cover (motor cable side).

      Note


      • Make sure to pull the upper inverter cover straight up, as a connector is connected to the bottom of the cover.

      • Do not touch the upper inverter cover waterproofing rubber.

  17. DISCONNECT MOTOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. A01HSAZ

      Using an insulated tool, remove the 3 bolts.

    2. A01HT8M

      Disconnect the 3 wire harness clamps and separate the motor cable.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  18. REMOVE NO. 3 MOTOR CABLE BRACKET


    1. A01HT7J

      Disconnect the hose clamp from the No. 3 motor cable bracket.

      Tech Tips

      Do not remove the hose clamp from the hose.

    2. Remove the 2 bolts and No. 3 motor cable bracket.

  19. REMOVE CONNECTOR COVER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01HSS3

      Remove the bolt and connector cover assembly.

      Note


      • Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  20. DISCONNECT NO. 4 ENGINE WIRE

    CAUTION:

    Wear insulated gloves.


    1. A01HW4O

      Disconnect the No. 4 engine wire.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

    2. A01HT6P

      Disconnect the wire harness clamp.

  21. DISCONNECT NO. 4 FLOOR WIRE

    CAUTION:

    Wear insulated gloves.


    1. A01HUFV

      Remove the bolt.

    2. A01HVAP

      Disconnect the wire harness clamp and connector.

      Note


      • Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.

      • Do not touch the connector waterproofing rubber or terminals.

      • Insulate the removed terminals with insulating tape.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

  22. TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01HUVW

      Temporarily install the connector cover assembly with the bolt to prevent any foreign matter or water from entering the inverter with converter assembly.

  23. DISCONNECT LOW VOLTAGE CONNECTOR

    Note


    • Insulate the removed terminals with insulating tape.

    • Do not allow any foreign matter or water to enter the inverter with converter assembly.


    1. A01HV4T

      Raise the lock lever and disconnect the 3 low voltage connectors.

    2. Disconnect the low voltage connector from the inverter with converter assembly.

  24. DISCONNECT NO. 3 ENGINE ROOM WIRE


    1. Remove the relay block cover.

    2. A01HTD7

      Remove the nut.

    3. Disconnect the wire harness clamp and No. 3 engine room wire.

  25. REMOVE NO. 4 INVERTER COOLING HOSE


    1. A01HVKME01
      Text in Illustration
      *1 Retainer

      Release the retainer and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly.

    2. A01HSUH

      Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.

  26. REMOVE NO. 1 INVERTER COOLING HOSE ASSEMBLY


    1. A01HT6RE01
      Text in Illustration
      *1 Retainer

      Release the retainer and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.

    2. A01HW06

      Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.

  27. REMOVE INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Wear insulated gloves.


    1. A01HUEGE01
      Text in Illustration
      *1 No. 3 Engine Room Wire
      *2 Hook

      Temporarily secure the No. 3 engine room wire with the inverter with converter assembly hook as shown in the illustration.

    2. A01HUTL

      Remove the 2 bolts, nut and inverter with converter assembly.

      Note


      • Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When removing the inverter with converter assembly, do not damage the parts around it.

      • To prevent damage, do not hold the inverter with converter assembly by the connectors.

      • To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

    3. A01HTGJ

      Even after the coolant is drained, coolant remains in the inverter with converter assembly due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter to prevent coolant from spilling out or foreign matter from entering the inverter with converter.

  28. REMOVE HIGH VOLTAGE FUSE

    CAUTION:

    Wear insulated gloves.

    Tech Tips

    Perform this procedure only when replacement of the high voltage fuse is necessary.


    1. A01HTM3

      Remove the bolt and connector cover assembly.

      Note


      • Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.

      • Do not allow any foreign matter or water to enter the inverter with converter assembly.

    2. A01HT25

      Remove the 2 nuts and high voltage fuse.

    3. A01HTM3

      Temporarily install the connector cover assembly with the bolt to prevent any foreign matter or water from entering the inverter with converter assembly.

  29. REMOVE AIR CLEANER BRACKET


    1. A01HSB2

      Remove the bolt and air cleaner bracket.

  30. REMOVE AIR CLEANER BRACKET


    1. A01HUY8

      Remove the bolt and air cleaner bracket.

  31. REMOVE NO. 1 INVERTER BRACKET


    1. A01HVP5

      Remove the 2 bolts and No. 1 inverter bracket.

  32. REMOVE NO. 2 INVERTER BRACKET


    1. A01HSQJ

      Remove the 2 bolts and No. 2 inverter bracket.

  33. REMOVE NO. 3 INVERTER BRACKET


    1. A01HVV1

      Remove the 2 bolts and No. 3 inverter bracket.

  34. REMOVE NO. 1 MOTOR CABLE BRACKET


    1. A01HUR2

      Remove the 2 bolts and No. 1 motor cable bracket.

  35. REMOVE NO. 2 MOTOR CABLE BRACKET


    1. A01HU1O

      Remove the 2 bolts and No. 2 motor cable bracket.

  36. REMOVE NO. 1 INVERTER COOLING HOSE


    1. A01HVHME01
      Text in Illustration
      *1 Retainer

      Release the retainer and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.

    2. Remove the No. 1 inverter cooling hose.

    3. A01HSUH

      Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.

  37. REMOVE NO. 3 ENGINE ROOM WIRE


    1. A01HVO2

      Open the cover.

      Note

      Do not twist the cover excessively when opening it.

    2. Remove the nut and No. 3 engine room wire.