HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A94-127

DTC Code DTC Name
P0A94-127 DC / DC Converter Performance

DESCRIPTION

For a description of the boost converter Click here.

If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the power management control ECU.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A94 127 Boost converter overvoltage signal detection (overvoltage due to system malfunction)
  • Hybrid battery junction block assembly

  • Inverter with converter assembly

  • Service plug grip

  • No. 4 Floor wire

  • Hybrid vehicle transaxle assembly

  • Generator cable

  • Motor cable

  • Wire harness or connector

  • INV fuse

  • Power management control ECU

MONITOR DESCRIPTION

If the boost converter detects overvoltage, it will transmit an overvoltage signal to the MG ECU. Upon receiving this signal, the power management control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY

Related DTCs P0A94 (INF 127): OVL detection (Over voltage malfunction)
Required sensors / components Boost converter
Frequency of operation Continuous
Duration TMC's intellectual property
MIL operation 1 driving cycle
Sequence of operation None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present TMC's intellectual property
Other conditions belong to TMC's intellectual property -

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property -

COMPONENT OPERATING RANGE

Power management control ECU DTC P0A94 (INF 127) is not detected

CONFIRMATION DRIVING PATTERN

A01HU7ZE02

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch on (IG) and turn the Techstream on.

  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

  4. Turn the power switch off.

  5. Turn the power switch on (IG) and check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc).

  6. Turn the power switch on (READY) and turn the Techstream on. [A]

  7. With the shift lever in P, wait for several seconds.

  8. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [B]

  9. Check that permanent DTCs are cleared.

  10. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

Tech Tips


  • If a permanent DTC is output, the system is malfunctioning.

  • If no permanent DTC is output, the system is normal.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 Click here.

Refer to the wiring diagram for DTC P0AA6-526 Click here.

Refer to the wiring diagram for DTC P324E-788 Click here.

Refer to the wiring diagram for DTC U0110-159 Click here.

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A94-127 only is output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range / Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72 (all INF codes)*1 Generator Phase V Current
      P0A75 (all INF codes)*1 Generator Phase W Current
      P0A78-113, 128, 266, 267, 279, 284, 286, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
      P0A7A-122, 130, 322, 324, 325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance
      P0A90-509 Drive Motor "A" Performance
      P0A92-521 Hybrid Generator Performance
      P0A94-172, 442, 547, 548, 549, 553, 554, 555, 556, 557, 564, 585, 587, 589, 590 DC / DC Converter Performance
      P0AA6-526 Hybrid Battery Voltage System Isolation Fault
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P3004-803 High Voltage Power Resource

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A94-127 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.


    B
    A
  2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      A01HVLPE01
      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector E1 from the inverter with converter assembly.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01HUMVE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E1-1 (GRF) - Body ground Power switch on (IG) Below 1 V
      E1-7 (GRFG) - Body ground Power switch on (IG) Below 1 V
      E1-2 (GSN) - Body ground Power switch on (IG) Below 1 V
      E1-8 (GSNG) - Body ground Power switch on (IG) Below 1 V
      E1-3 (GCS) - Body ground Power switch on (IG) Below 1 V
      E1-9 (GCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  4. CHECK GENERATOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector E1 from the inverter with converter assembly.

    3. A01HUMVE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      E1-1 (GRF) - E1-7 (GRFG) Power switch off 4.2 to 12.5 Ω
      E1-2 (GSN) - E1-8 (GSNG) Power switch off 9.8 to 20.1 Ω
      E1-3 (GCS) - E1-9 (GCSG) Power switch off 9.8 to 20.1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      E1-1 (GRF) or E1-7 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-2 (GSN) or E1-8 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-3 (GCS) or E1-9 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector E1 from the inverter with converter assembly.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01HUMVE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E1-4 (MRF) - Body ground Power switch on (IG) Below 1 V
      E1-11 (MRFG) - Body ground Power switch on (IG) Below 1 V
      E1-5 (MSN) - Body ground Power switch on (IG) Below 1 V
      E1-12 (MSNG) - Body ground Power switch on (IG) Below 1 V
      E1-6 (MCS) - Body ground Power switch on (IG) Below 1 V
      E1-13 (MCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  6. CHECK MOTOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector E1 from the inverter with converter assembly.

    3. A01HUMVE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      E1-4 (MRF) - E1-11 (MRFG) Power switch off 4.2 to 12.5 Ω
      E1-5 (MSN) - E1-12 (MSNG) Power switch off 9.8 to 20.1 Ω
      E1-6 (MCS) - E1-13 (MCSG) Power switch off 9.8 to 20.1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      E1-4 (MRF) or E1-11 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-5 (MSN) or E1-12 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-6 (MCS) or E1-13 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  7. CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HTG6

      Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.

    3. A01HV6R

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the generator cable from the inverter with converter assembly.

    5. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the inverter with converter assembly.

    7. Install the upper inverter cover.


    B
    C
    A
  8. CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUQS

      Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.

    3. A01HSDQ

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the motor cable from the inverter with converter assembly.

    5. Check for arc marks at the terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the motor cable to the inverter with converter assembly.

    7. Install the upper inverter cover.


    B
    C
    A
  9. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUG6

      Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.

    3. A01HU5SE05
      Text in Illustration
      *1 Generator Cable
      *2 Motor Cable

      Disconnect the generator cable and motor cable from the inverter with converter assembly.

    4. A01HTA8E05
      Text in Illustration
      *1 Shield Ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      Check MG1 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        o1-1 (W) - o1-3 (U) Power switch off 59.1 to 67.5 mΩ
        o1-2 (V) - o1-1 (W) Power switch off 59.1 to 67.5 mΩ
        o1-3 (U) - o1-2 (V) Power switch off 62.1 to 70.5 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable and motor cable.

    7. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).


    NG
    OK
  10. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUG6

      Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.

    3. A01HU5SE05
      Text in Illustration
      *1 Generator Cable
      *2 Motor Cable

      Disconnect the generator cable and motor cable from the inverter with converter assembly.

    4. A01HTA8E06
      Text in Illustration
      *1 Shield Ground
      *a

      Motor Cable

      (Inverter with Converter Assembly Side)

      Check MG2 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        n1-1 (W) - n1-3 (U) Power switch off 71.4 to 81.0 mΩ
        n1-2 (V) - n1-1 (W) Power switch off 71.4 to 81.0 mΩ
        n1-3 (U) - n1-2 (V) Power switch off 74.4 to 84.1 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      n1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      n1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      n1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable and motor cable.

    7. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).


    NG
    OK
  11. CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 4 FLOOR WIRE CONNECTOR CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HU0Q

      Remove the connector cover assembly from the inverter with converter assembly.

    3. A01HTEHE01

      Check that the bolt for the No. 4 floor wire is tightened to the specified torque, the No. 4 floor wire is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
    4. Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.

    5. Check for arc marks at the bolt and terminals for the No. 4 floor wire.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the No. 4 floor wire to the inverter with converter assembly.

    7. Install the connector cover assembly.


    B
    C
    A
  12. CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.

    NG
    OK
  13. INSPECT SERVICE PLUG GRIP


    1. Remove the service plug drip.

    2. A01HSE3E01
      Text in Illustration
      *1 Service plug grip

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Service plug grip terminals Always Below 1 Ω
    3. Install the service plug drip.


    NG
    OK
  14. CHECK NO. 4 FLOOR WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 4 hybrid battery shield panel Click here.

    3. A01HW87E04

      Disconnect connectors Q2 and Q3 of the No. 4 floor wire from the hybrid battery junction block assembly.

    4. A01HU0Q

      Remove the connector cover assembly from the inverter with converter assembly.

    5. A01HTEHE01

      Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.

    6. A01HW0ME01
      Text in Illustration
      *1 Shield Ground
      *a

      No. 4 Floor Wire

      (Inverter with Converter Assembly Side)

      *b

      No. 4 Floor Wire

      (Hybrid Battery Junction Block Assembly Side)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      Q1-1 (CBI) - Q2-1 (CBI) (Positive terminal) Power switch off Below 1 Ω
      Q1-2 (CEI) - Q3-1 (CEI) (Negative terminal) Power switch off Below 1 Ω
    7. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      Q2-1 (CBI) - Body ground and shield ground Power switch off 10 MΩ or higher
      Q3-1 (CEI) - Body ground and shield ground Power switch off 10 MΩ or higher
      Q2-1 (CBI) - Q3-1 (CEI) Power switch off 10 MΩ or higher
    8. Connect the No. 4 floor wire to the hybrid battery junction block assembly.

    9. Connect the No. 4 floor wire to the inverter with converter assembly.

    10. Install the connector cover assembly.

    11. Install the No. 4 hybrid battery shield panel.


    NG
    OK
  15. INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid battery junction block assembly Click here.

    3. A01HUDUE05
      Text in Illustration
      *a

      Component without harness connected

      (Hybrid Battery Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 (+) - Q2-1 (CBI) Auxiliary battery voltage is not applied between terminals O9-1 (SMRB) and O9-2 (GND) 10 kΩ or higher
      A-1 (+) - Q2-1 (CBI) Auxiliary battery voltage is applied between terminals O9-1 (SMRB) and O9-2 (GND) Below 1 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O9-1 (SMRB) - O9-2 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω
    5. Install the hybrid battery junction block assembly.


    NG
    OK
  16. INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRG)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid battery junction block assembly Click here.

    3. A01HUDUE06
      Text in Illustration
      *a

      Component without harness connected

      (Hybrid Battery Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      q1-1 (-) - Q3-1 (CEI) Auxiliary battery voltage is not applied between terminals O9-3 (SMRG) and O9-2 (GND) 10 kΩ or higher
      q1-1 (-) - Q3-1 (CEI) Auxiliary battery voltage is applied between terminals O9-3 (SMRG) and O9-2 (GND) Below 1 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O9-3 (SMRG) - O9-2 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω
    5. Install the hybrid battery junction block assembly.


    NG
    OK
  17. CHECK FUSE (INV)


    1. A01HUB1E01
      Text in Illustration
      *1 No. 2 Engine Room Relay Block
      *2 INV fuse

      Remove the INV fuse from the No. 2 engine room relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      INV fuse terminal Always Below 1Ω
    3. Install the INV fuse.


    NG
    OK
  18. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from inverter with converter assembly.

    3. A01HW05E06
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-10 (GND1) - Body ground Power switch off Below 1 Ω
      A14-11 (GND2) - Body ground Power switch off Below 1 Ω
    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG).

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A14-30 (+B) - Body ground Power switch on (IG) 11 to 14 V
      A14-31 (+B2) - Body ground Power switch on (IG) 11 to 14 V

      Note

      Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.

    8. Disconnect the cable from the negative (-) auxiliary battery terminal.

    9. Connect the inverter with converter assembly connector.


    NG
    OK
  19. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A39 from the power management control ECU.

    3. Disconnect connector A14 from the inverter with converter assembly.

    4. A01HVDBE01
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      A39-24 (HTM+) - A14-9 (HTM+) Power switch off Below 1 Ω
      A39-25 (HTM-) - A14-20 (HTM-) Power switch off Below 1 Ω
      A39-30 (MTH+) - A14-8 (MTH+) Power switch off Below 1 Ω
      A39-29 (MTH-) - A14-19 (MTH-) Power switch off Below 1 Ω
      A39-33 (REQ+) - A14-26 (REQ+) Power switch off Below 1 Ω
      A39-32 (REQ-) - A14-37 (REQ-) Power switch off Below 1 Ω
      A39-21 (CLK+) - A14-7 (CLK+) Power switch off Below 1 Ω
      A39-20 (CLK-) - A14-18 (CLK-) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      A39-24 (HTM+) or A14-9 (HTM+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-25 (HTM-) or A14-20 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-30 (MTH+) or A14-8 (MTH+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-29 (MTH-) or A14-19 (MTH-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-33 (REQ+) or A14-26 (REQ+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-32 (REQ-) or A14-37 (REQ-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-21 (CLK+) or A14-7 (CLK+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A39-20 (CLK-) or A14-18 (CLK-) - Body ground and other terminals Power switch off 10 kΩ or higher
    5. Connect the cable to the negative (-) auxiliary battery terminal.

    6. Turn the power switch on (IG).

    7. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A39-24 (HTM+) or A14-9 (HTM+) - Body ground Power switch on (IG) Below 1 V
      A39-25 (HTM-) or A14-20 (HTM-) - Body ground Power switch on (IG) Below 1 V
      A39-30 (MTH+) or A14-8 (MTH+) - Body ground Power switch on (IG) Below 1 V
      A39-29 (MTH-) or A14-19 (MTH-) - Body ground Power switch on (IG) Below 1 V
      A39-33 (REQ+) or A14-26 (REQ+) - Body ground Power switch on (IG) Below 1 V
      A39-32 (REQ-) or A14-37 (REQ-) - Body ground Power switch on (IG) Below 1 V
      A39-21 (CLK+) or A14-7 (CLK+) - Body ground Power switch on (IG) Below 1 V
      A39-20 (CLK-) or A14-18 (CLK-) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    8. Turn the power switch off.

    9. Disconnect the cable from the negative (-) auxiliary battery terminal.

    10. Connect the inverter with converter assembly connector.

    11. Connect the power management control ECU connector.


    NG
    OK
  20. CHECK POWER MANAGEMENT CONTROL ECU


    1. Disconnect connector A39 from the power management control ECU.

    2. A01HSYYE10
      Text in Illustration
      *a

      Component without harness connected

      (Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A39-24 (HTM+) - A39-25 (HTM-) Power switch off 80 to 170 Ω
      A39-30 (MTH+) - A39-29 (MTH-) Power switch off 80 to 170 Ω
      A39-33 (REQ+) - A39-32 (REQ-) Power switch off 80 to 170 Ω
      A39-21 (CLK+) - A39-20 (CLK-) Power switch off 80 to 170 Ω
    3. Connect the power management control ECU connector.


    NG
    OK
  21. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A01HT4O

      Check the connection of the generator resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  22. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A01HSIA

      Check the connection of the motor resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  23. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A01HT4O

      Check the connection of the generator resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  24. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector E1 from the inverter with converter assembly.

    3. A01HSKRE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to Generator Resolver)

      Disconnect the generator resolver connector.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      E1-1 (GRF) - E13-1 (GRF) Power switch off Below 1 Ω
      E1-7 (GRFG) - E13-5 (GRFG) Power switch off Below 1 Ω
      E1-2 (GSN) - E13-2 (GSN) Power switch off Below 1 Ω
      E1-8 (GSNG) - E13-6 (GSNG) Power switch off Below 1 Ω
      E1-3 (GCS) - E13-3 (GCS) Power switch off Below 1 Ω
      E1-9 (GCSG) - E13-7 (GCSG) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      E1-1 (GRF) or E13-1 (GRF) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-7 (GRFG) or E13-5 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-2 (GSN) or E13-2 (GSN) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-8 (GSNG) or E13-6 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-3 (GCS) or E13-3 (GCS) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-9 (GCSG) or E13-7 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher

      Tech Tips

      The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

    5. Connect the generator resolver connector.

    6. Connect the inverter with converter assembly connector.


    NG
    OK
  25. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A01HSIA

      Check the connection of the motor resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  26. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector E1 from the inverter with converter assembly.

    3. A01HU2TE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to Motor Resolver)

      Disconnect the motor resolver connector.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      E1-4 (MRF) - E12-1 (MRF) Power switch off Below 1 Ω
      E1-11 (MRFG) - E12-4 (MRFG) Power switch off Below 1 Ω
      E1-5 (MSN) - E12-2 (MSN) Power switch off Below 1 Ω
      E1-12 (MSNG) - E12-5 (MSNG) Power switch off Below 1 Ω
      E1-6 (MCS) - E12-3 (MCS) Power switch off Below 1 Ω
      E1-13 (MCSG) - E12-6 (MCSG) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      E1-4 (MRF) or E12-1 (MRF) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-11 (MRFG) or E12-4 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-5 (MSN) or E12-2 (MSN) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-12 (MSNG) or E12-5 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-6 (MCS) or E12-3 (MCS) - Body ground and other terminals Power switch off 1 MΩ or higher
      E1-13 (MCSG) or E12-6 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher

      Tech Tips

      The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

    5. Connect the motor resolver connector.

    6. Connect the inverter with converter assembly connector.


    NG
    OK
  27. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the inverter with converter assembly Click here.

    3. A01HTY1

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.5 N*m (87 kgf*cm, 75 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 10.5 N*m (65 and 107 kgf*cm, 5 and 8 ft.*lbf).

    4. Disconnect the generator cable from the hybrid vehicle transaxle assembly.

    5. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the hybrid vehicle transaxle assembly.

    7. Install the inverter with converter assembly.


    B
    C
    A
  28. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the generator cable Click here.

    3. A01HST8E01
      Text in Illustration
      *1 Shield ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      *b

      Generator Cable

      (Hybrid Vehicle Transaxle Assembly Side)

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the generator cable with insulating tape to prevent them from coming into contact with body ground

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o1-1 (W) - o2-1 (W) Power switch off Below 1 Ω
      o1-2 (V) - o2-2 (V) Power switch off Below 1 Ω
      o1-3 (U) - o2-3 (U) Power switch off Below 1 Ω
      o1-1 (W) - o2-3 (U) Power switch off 100 MΩ or higher
      o1-2 (V) - o2-1 (W) Power switch off 100 MΩ or higher
      o1-3 (U) - o2-2 (V) Power switch off 100 MΩ or higher
    5. Install the generator cable.


    NG
    OK
  29. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HULB

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.5 N*m (87 kgf*cm, 75 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 10.5 N*m (65 and 107 kgf*cm, 5 and 8 ft.*lbf).

    3. Disconnect the motor cable from the hybrid vehicle transaxle assembly.

    4. Check for arc marks at the terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    5. Connect the motor cable to the hybrid vehicle transaxle assembly.


    B
    C
    A
  30. CHECK MOTOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the motor cable Click here.

    3. A01HUGQE01
      Text in Illustration
      *1 Shield ground
      *a

      Motor Cable

      (Inverter with Converter Assembly Side)

      *b

      Motor Cable

      (Hybrid Vehicle Transaxle Assembly Side)

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      n1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      n1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      n1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      n1-1 (W) - n2-3 (W) Power switch off Below 1 Ω
      n1-2 (V) - n2-2 (V) Power switch off Below 1 Ω
      n1-3 (U) - n2-1 (U) Power switch off Below 1 Ω
      n1-1 (W) - n2-1 (U) Power switch off 100 MΩ or higher
      n1-2 (V) - n2-3 (W) Power switch off 100 MΩ or higher
      n1-3 (U) - n2-2 (V) Power switch off 100 MΩ or higher
    5. Install the motor cable.


    NG
    OK
  31. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - INV FUSE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. A01HW05E07
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-30 (+B) - Body ground Power switch off 10 kΩ or higher
      A14-31 (+B2) - Body ground Power switch off 10 kΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  32. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  33. REPAIR OR REPLACE HARNESS OR CONNECTOR


    NEXT