HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A7A-203

DTC Code DTC Name
P0A7A-203 Generator Inverter Performance

DESCRIPTION

For a description of the inverter Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A7A 203 Malfunction (short circuit) in the generator inverter inside the inverter with converter assembly
  • Inverter with converter assembly

  • Hybrid vehicle transaxle assembly

  • Generator cable

MONITOR DESCRIPTION

The MG ECU monitors the generator inverter electric current. If the current exceeds the threshold for a specified period of time, the power management control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY

Related DTCs P0A7A (INF 203): GFIV detection (Short circuit malfunction)
Required sensors / components Generator inverter
Frequency of operation Continuous
Duration TMC's intellectual property
MIL operation 1 driving cycle
Sequence of operation None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present TMC's intellectual property
Other conditions belong to TMC's intellectual property -

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property -

COMPONENT OPERATING RANGE

Power management control ECU DTC P0A7A (INF 203) is not detected

CONFIRMATION DRIVING PATTERN

A01HU7ZE02

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch on (IG) and turn the Techstream on.

  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

  4. Turn the power switch off.

  5. Turn the power switch on (IG) and check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc).

  6. Turn the power switch on (READY) and turn the Techstream on. [A]

  7. With the shift lever in P, wait for several seconds.

  8. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [B]

  9. Check that permanent DTCs are cleared.

  10. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

Tech Tips


  • If a permanent DTC is output, the system is malfunctioning.

  • If no permanent DTC is output, the system is normal.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526 Click here.

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note


  • After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

  • DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810 and 811 are stored. After troubleshooting and repairing DTC P0A7A-203, be sure to troubleshoot all the other DTCs.

  • Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the inverter with converter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the inverter with converter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.

  • After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 40 km/h (25 mph) for 1 minute and check that DTC P0A92-261 (Hybrid Generator Performance) is not output. If DTC P0A92-261 (Hybrid Generator Performance) is output, replace the hybrid vehicle transaxle assembly.

PROCEDURE


  1. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUG6

      Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.

    3. A01HU5SE05
      Text in Illustration
      *1 Generator Cable
      *2 Motor Cable

      Disconnect the generator cable and motor cable from the inverter with converter assembly.

    4. A01HTA8E05
      Text in Illustration
      *1 Shield Ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      Check MG1 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        o1-1 (W) - o1-3 (U) Power switch off 59.1 to 67.5 mΩ
        o1-2 (V) - o1-1 (W) Power switch off 59.1 to 67.5 mΩ
        o1-3 (U) - o1-2 (V) Power switch off 62.1 to 70.5 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable and motor cable.

    7. Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).


    NG
    OK
  2. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  3. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check the other DTCs that were output together with DTC P0A7A-203.

      Result
      DTC No. Relevant Diagnosis
      P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810, 811 Generator Inverter Performance

      Note

      DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810 and 811 are stored. After troubleshooting and repairing DTC P3245-203, be sure to troubleshoot all the other DTCs.


    NEXT
  4. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the generator cable Click here.

    3. A01HST8E01
      Text in Illustration
      *1 Shield ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      *b

      Generator Cable

      (Hybrid Vehicle Transaxle Assembly Side)

      Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      o1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the generator cable with insulating tape to prevent them from coming into contact with body ground

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o1-1 (W) - o2-1 (W) Power switch off Below 1 Ω
      o1-2 (V) - o2-2 (V) Power switch off Below 1 Ω
      o1-3 (U) - o2-3 (U) Power switch off Below 1 Ω
      o1-1 (W) - o2-3 (U) Power switch off 100 MΩ or higher
      o1-2 (V) - o2-1 (W) Power switch off 100 MΩ or higher
      o1-3 (U) - o2-2 (V) Power switch off 100 MΩ or higher
    5. Install the generator cable.


    NG
    OK
  5. REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY

    Click here


    NEXT
  6. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  7. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check the other DTCs that were output together with DTC P0A7A-203.

      Result
      DTC No. Relevant Diagnosis
      P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810, 811 Generator Inverter Performance

      Note

      DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810 and 811 are stored. After troubleshooting and repairing DTC P3245-203, be sure to troubleshoot all the other DTCs.


    NEXT
  8. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the inverter with converter assembly.

    3. Disconnect the generator cable from the hybrid vehicle transaxle assembly.

    4. A01HV1GE01
      Text in Illustration
      *a

      Component without generator cable connected

      (Hybrid Vehicle Transaxle Assembly)

      Check MG1 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        o2-1 (W) - o2-3 (U) Power switch off 56.0 to 62.0 mΩ
        o2-2 (V) - o2-1 (W) Power switch off 59.0 to 65.0 mΩ
        o2-3 (U) - o2-2 (V) Power switch off 56.0 to 62.0 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at x 20°C (68°F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    5. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      o2-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      o2-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      o2-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    6. Connect the generator cable.

    7. Install the inverter with converter assembly.


    NG
    OK
  9. REPLACE GENERATOR CABLE

    Click here


    NEXT
  10. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  11. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check the other DTCs that were output together with DTC P0A7A-203.

      Result
      DTC No. Relevant Diagnosis
      P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810, 811 Generator Inverter Performance

      Note

      DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810 and 811 are stored. After troubleshooting and repairing DTC P3245-203, be sure to troubleshoot all the other DTCs.


    NEXT
  12. REPLACE GENERATOR CABLE

    Click here


    NEXT
  13. REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY

    Click here


    NEXT
  14. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  15. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check the other DTCs that were output together with DTC P0A7A-203.

      Result
      DTC No. Relevant Diagnosis
      P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810, 811 Generator Inverter Performance

      Note

      DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 130, 322, 324, 325, 517, 518, 809, 810 and 811 are stored. After troubleshooting and repairing DTC P3245-203, be sure to troubleshoot all the other DTCs.


    NEXT